15A/10A 8-Outlet 1U Metered eco PDU - PE5108

15A/10A 8-Outlet 1U Metered eco PDU - PE5108

• 1U 8-Outlet eco PDU
• Bank level metering

ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE5108 eco PDUs are intelligent PDUs that contain 8 AC outlets and are available in various IEC or NEMA socket configurations. They provide secure centralized intelligent power management (power on off cycle) of data center IT equipment (servers storage systems KVM switches network devices serial data devices etc.) as well as the ability to monitor the center"s health environment via sensors*.
eco PDUs offer remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDUs either at the PDU device or outlet level from practically any location via a TCP/IP connection.

eco PDU supports any 3rd party v3 SNMP Manager Software and eco Sensors (Energy Management Software). eco Sensors provides you with an easy method for managing multiple devices offering an intuitive and user friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it. With eco Sensors the Sensor-enabled eco PDU also offers comprehensive power analysis reports which can separate by departments and locations providing precise measurements of current voltage power and watt-hour in a real-time display.

With its advanced security features and ease of operation the eco PDU is the most convenient most reliable and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.

* Sensors are optional accessories. A sensor-enabled installation is required to generate a more complete energy-efficient data and chart. Higher sensor installation density is helpful to generate more accurate data.

Diagram

 PE5108 Diagram

Specifications

Function PE5108A PE5108B PE5108G
Electrical
Nominal Input Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 15A Max; 12A(UL de-rated) 15A Max; 12A(UL de-rated) 10A Max
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection NEMA 5-15P NEMA 6-15P IEC 60320 C14
Input Power 1800 VA(Max); 1440 VA(UL de-rated) 3120 VA(Max); 2496 VA(UL de-rated) 2300 VA(Max)
Outlet Type Total: 8 x NEMA 5-15R Total: 8 x IEC320 C13 Total: 8 x IEC320 C13
Nominal Output Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) NEMA 5-15R: 15A(Max); 12A(UL de-rated) C13 : 15A(Max); 12A(UL de-rated) C13 : 10A(Max)
Maximum Output Current (Bank) 15A(Max); 12A(UL de-rated) 15A(Max); 12A(UL de-rated) 10A(Max)
Maximum Output Current (Total) 15A(Max); 12A(UL de-rated) 15A(Max); 12A(UL de-rated) 10A(Max)
Breakers 1 x 15A Non-Fuse Breaker 1 x 15A Non-Fuse Breaker 1 x 15A Non-Fuse Breaker
Metering Bank level Current, Voltage, VA , PF and KWh Monitoring Bank level Current, Voltage, VA , PF and KWh Monitoring Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet Switching None None None
Environment Sensor Ports 2 2 2
Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) TBD TBD TBD
Weight TBD TBD TBD
Power Cord Length 3 m 3 m 3 m
Environmental
Temperature (Operating / Storage) 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C 0 – 50°C / -20 – 60°C
Humidity (Operating & Storage) 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing
Compliance
EMC Verification FCC, Others by Request FCC, Others by Request CE, Others by Request
Safety Verification TUV-CB, cTUVus, Others by Request TUV-CB, cTUVus, Others by Request TUV-CB, CE-LVD, Others by Request
£390.37