Account Logout

You have been logged off your account. It is now safe to leave the computer.

Your shopping cart has been saved, the items inside it will be restored whenever you log back into your account.

Shopping Cart
20A/16A 16-Outlet Metered-Ready Energy PDU - PE1216 (EX-VAT)

20A/16A 16-Outlet Metered-Ready Energy PDU - PE1216 (EX-VAT)

• PE1216A: 100~120V; North America Mexico Japan Taiwan
• PE1216B: 200~240V; North America Mexico Japan Taiwan
• PE1216G: International

The PE1216 Energy PDU contains 16 AC outlets and is available in IEC or NEMA socket configurations. The PE1216 Energy PDU features a space-saving 0U design that allows it to be mounted vertically on the outside of a rack resulting in a more efficient use of space in the server room while providing 16 AC outlets. The PE1216 Energy PDU can be integrated into an installation with the EC1000 Energy Box* allowing you to monitor the real-time current and environmental conditions of the Energy PDU from the front panel of the EC1000 at the rack or via Web GUI remotely – making your server room efficiently green with ease.

* ATEN EC1000 Energy Box and energy management software – eco Sensors are available at www..aten.com.

Diagram

 PE1216 Diagram

Specifications

Function PE1216A PE1216B PE1216G
Electrical
Nominal Input Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 20A(Max) 20A(Max) 16A(Max)
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection NEMA 5-20P NEMA 6-20P IEC 60320 C20
Input Power 2400 VA(Max) 4160 VA(Max) 3680 VA(Max)
Outlet Type Total: 16 x NEMA 5-15R Total: 16 x IEC320 C13 Total: 16 x IEC320 C13
Nominal Output Voltage 100 – 120 VAC 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) 15A(Max) 15A(Max) 10A(Max)
Maximum Output Current (Bank) 20A(Max) 20A(Max) 16A(Max)
Maximum Output Current (Total) 20A(Max) 20A(Max) 16A(Max)
Breakers 1 x 20A Non-Fuse Breaker 1 x 20A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker
Metering Bank Level Current Monitoring (Via EC1000 Energy Box) Bank Level Current Monitoring (Via EC1000 Energy Box) Bank Level Current Monitoring (Via EC1000 Energy Box)
Outlet Switching None None None
Environment Sensor Ports 0 0 0
Metering Accuracy Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) 73.00 x 4.40 x 4.40 cm
(28.74 x 1.73 x 1.73 in.)
73.00 x 4.40 x 4.40 cm
(28.74 x 1.73 x 1.73 in.)
73.00 x 4.40 x 4.40 cm
(28.74 x 1.73 x 1.73 in.)
Weight 1.32 kg ( 2.91 lb ) 1.32 kg ( 2.91 lb ) 1.32 kg ( 2.91 lb )
Power Cord Length 3 m 3 m 3 m
Environmental
Temperature (Operating / Storage) 0–50°C / -20–60°C 0–50°C / -20–60°C 0–50°C / -20–60°C
Humidity (Operating & Storage) 0–80% RH, Non-Condensing 0–80% RH, Non-Condensing 0–80% RH, Non-Condensing
Compliance
EMC Verification FCC, Others by Request FCC, Others by Request CE, C-Tick, Others by Request
Safety Verification cTUVus, PSE, Others by Request cTUVus, PSE, Others by Request TUV-CB, GOST, Others by Request
£0.00